{"id":2140,"date":"2023-10-09T14:00:53","date_gmt":"2023-10-09T11:00:53","guid":{"rendered":"https:\/\/roi.gr\/?p=2140"},"modified":"2023-10-09T14:00:53","modified_gmt":"2023-10-09T11:00:53","slug":"spa-pool-pumps","status":"publish","type":"post","link":"https:\/\/roi.gr\/en\/spa-pool-pumps\/","title":{"rendered":"SPA pool pumps"},"content":{"rendered":"<p>Reverse direction pumps with high energy efficiency motors of compact construction. Suitable for hydromassage, jacuzzi, SPA.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>General characteristics<\/strong><\/p>\n<p>Maximum operating pressure 2.5 bar.<br \/>\nMaximum water temperature +60OC.<br \/>\nAsynchronous bipolar motor, insulation class F, protection IPX5.<br \/>\nThe single-phase pumps have a built-in starting capacitor and thermal protection.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Construction materials<\/strong><\/p>\n<p>ABS (Acrylonitrile Butadiene Styrene) pump body.<br \/>\nGuide vane and impeller reinforced thermoplastic PPO &#8211; GF30 &#8211; NORYL.<br \/>\nMechanical seal ceramic \/ carbon \/ FPM.<\/p>\n<p><img decoding=\"async\" src=\"http:\/\/roi-pumps.eu\/images\/partners\/CALPEDA.png\" \/><\/p>\n<table class=\"extraFieldsDataSets\">\n<thead>\n<tr>\n<td class=\"extraFieldsDSLabels\"><strong>CODE<\/strong><\/td>\n<td class=\"extraFieldsDSLabels\"><strong>TYPE PUMP<\/strong><\/td>\n<td class=\"extraFieldsDSLabels\"><strong>PUMP VOLTAGE (Volt)<\/strong><\/td>\n<td class=\"extraFieldsDSLabels\"><strong>MOTOR POWER (kW)<\/strong><\/td>\n<td class=\"extraFieldsDSLabels\"><strong>NOISE<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"extraFieldsDSValues\">66C200100-0<\/td>\n<td class=\"extraFieldsDSValues\">SPAM 11<\/td>\n<td class=\"extraFieldsDSValues\">1 x 230<\/td>\n<td class=\"extraFieldsDSValues\">0,45<\/td>\n<td class=\"extraFieldsDSValues\">G50<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">66B200100-0<\/td>\n<td class=\"extraFieldsDSValues\">SPA 11<\/td>\n<td class=\"extraFieldsDSValues\">3 x 400<\/td>\n<td class=\"extraFieldsDSValues\">0,45<\/td>\n<td class=\"extraFieldsDSValues\">G50<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">66C200200-0<\/td>\n<td class=\"extraFieldsDSValues\">SPAM 21\/A<\/td>\n<td class=\"extraFieldsDSValues\">1 x 230<\/td>\n<td class=\"extraFieldsDSValues\">0,55<\/td>\n<td class=\"extraFieldsDSValues\">G50<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">66B200200-0<\/td>\n<td class=\"extraFieldsDSValues\">SPA 21\/A<\/td>\n<td class=\"extraFieldsDSValues\">3 x 400<\/td>\n<td class=\"extraFieldsDSValues\">0,55<\/td>\n<td class=\"extraFieldsDSValues\">G50<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">66C200300-0<\/td>\n<td class=\"extraFieldsDSValues\">SPAM 31\/A<\/td>\n<td class=\"extraFieldsDSValues\">1 x 230<\/td>\n<td class=\"extraFieldsDSValues\">0,75<\/td>\n<td class=\"extraFieldsDSValues\">G50<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">66B200310-0<\/td>\n<td class=\"extraFieldsDSValues\">SPA 31\/B<\/td>\n<td class=\"extraFieldsDSValues\">3 x 400<\/td>\n<td class=\"extraFieldsDSValues\">0,75<\/td>\n<td class=\"extraFieldsDSValues\">G50<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">66C200400-0<\/td>\n<td class=\"extraFieldsDSValues\">SPAM 41<\/td>\n<td class=\"extraFieldsDSValues\">1 x 230<\/td>\n<td class=\"extraFieldsDSValues\">1,10<\/td>\n<td class=\"extraFieldsDSValues\">G50<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">66B200410-0<\/td>\n<td class=\"extraFieldsDSValues\">SPA 41\/A<\/td>\n<td class=\"extraFieldsDSValues\">3 x 400<\/td>\n<td class=\"extraFieldsDSValues\">1,10<\/td>\n<td class=\"extraFieldsDSValues\">G50<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"clr\"><\/div>\n<div class=\"itemExtraFields\">\n<ul>\n<li class=\"even typeTextarea group5 manometrikosemys\">\n<table class=\"specs-table\">\n<thead>\n<tr class=\"tableizer-firstrow\">\n<th colspan=\"9\">PROVISION in m3\/h<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><\/td>\n<td>0<\/td>\n<td>6,0<\/td>\n<td>9,0<\/td>\n<td>12,0<\/td>\n<td>13,0<\/td>\n<td>16,0<\/td>\n<td>17,0<\/td>\n<td>18,0<\/td>\n<\/tr>\n<tr>\n<td><strong>CODE NUMBER<\/strong><\/td>\n<td colspan=\"8\"><strong><span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">MANOMETRIC in M.Y.S.<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">(m)<\/span><\/span><\/span><\/strong><\/td>\n<\/tr>\n<tr>\n<td>66C200100-0<\/td>\n<td>12<\/td>\n<td>9,7<\/td>\n<td>7,8<\/td>\n<td>5,6<\/td>\n<td>4,7<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>66B200100-0<\/td>\n<td>12<\/td>\n<td>9,7<\/td>\n<td>7,8<\/td>\n<td>5,6<\/td>\n<td>4,7<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>66C200200-0<\/td>\n<td>14,5<\/td>\n<td>12,1<\/td>\n<td>10,2<\/td>\n<td>7,9<\/td>\n<td>7,2<\/td>\n<td>5,0<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>66B200200-0<\/td>\n<td>14,5<\/td>\n<td>12,1<\/td>\n<td>10,2<\/td>\n<td>7,9<\/td>\n<td>7,2<\/td>\n<td>5,0<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>66C200300-0<\/td>\n<td>16,1<\/td>\n<td>13,9<\/td>\n<td>12,4<\/td>\n<td>10,2<\/td>\n<td>9,3<\/td>\n<td>6,8<\/td>\n<td>5,8<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>66B200310-0<\/td>\n<td>16,1<\/td>\n<td>13,9<\/td>\n<td>12,4<\/td>\n<td>10,2<\/td>\n<td>9,3<\/td>\n<td>6,8<\/td>\n<td>5,8<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>66C200400-0<\/td>\n<td>17,3<\/td>\n<td>15,3<\/td>\n<td>14,0<\/td>\n<td>12,4<\/td>\n<td>11,8<\/td>\n<td>9,5<\/td>\n<td>8,6<\/td>\n<td>7,7<\/td>\n<\/tr>\n<tr>\n<td>66B200410-0<\/td>\n<td>17,3<\/td>\n<td>15,3<\/td>\n<td>14,0<\/td>\n<td>12,4<\/td>\n<td>11,8<\/td>\n<td>9,5<\/td>\n<td>8,6<\/td>\n<td>7,7<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/li>\n<li class=\"odd typeSelect group5 kataskevastis\"><span class=\"itemExtraFieldsLabel\"><strong>Manufacturer<\/strong>:<\/span> <span class=\"itemExtraFieldsValue\">CALPEDA<\/span><\/li>\n<\/ul>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Reverse direction pumps with high energy efficiency motors of compact construction. Suitable for hydromassage, jacuzzi, SPA. &nbsp; General characteristics Maximum operating pressure 2.5 bar. Maximum water temperature +60OC. Asynchronous bipolar motor, insulation class F, protection IPX5. The single-phase pumps have a built-in starting capacitor and thermal protection. &nbsp; Construction materials ABS (Acrylonitrile Butadiene Styrene) pump [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":2141,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[53],"tags":[],"class_list":["post-2140","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-pool-pumps-in-line-circulators"],"_links":{"self":[{"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/posts\/2140","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/comments?post=2140"}],"version-history":[{"count":2,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/posts\/2140\/revisions"}],"predecessor-version":[{"id":2144,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/posts\/2140\/revisions\/2144"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/media\/2141"}],"wp:attachment":[{"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/media?parent=2140"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/categories?post=2140"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/tags?post=2140"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}