{"id":1988,"date":"2023-10-09T09:18:34","date_gmt":"2023-10-09T06:18:34","guid":{"rendered":"https:\/\/roi.gr\/?p=1988"},"modified":"2023-10-09T09:18:34","modified_gmt":"2023-10-09T06:18:34","slug":"horizontal-self-priming-centrifugal-pumps-ap-97-98","status":"publish","type":"post","link":"https:\/\/roi.gr\/en\/horizontal-self-priming-centrifugal-pumps-ap-97-98\/","title":{"rendered":"Horizontal self-priming centrifugal pumps AP 97-98"},"content":{"rendered":"<p>Horizontal self-priming open impeller pumps with high energy efficiency motors. Suitable for clean and dirty fluids.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>General characteristics<\/strong><\/p>\n<p>Maximum operating pressure 6 bar<br \/>\nMaximum water temperature +70OC.<br \/>\nMaximum suction depth 8 m, includes non-return valve.<br \/>\nAsynchronous bipolar motor, insulation class F, protection IP44.<br \/>\nSingle-phase pumps have a built-in start capacitor.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Construction materials<\/strong><\/p>\n<p>Pump body and impeller made of G 20 cast iron<br \/>\nAISI 416 stainless steel shaft<br \/>\nMechanical seal silicon carbide \/ ceramic<\/p>\n<p><img decoding=\"async\" src=\"http:\/\/roi-pumps.eu\/images\/partners\/SAER.png\" \/><\/p>\n<table class=\"extraFieldsDataSets\">\n<thead>\n<tr>\n<td class=\"extraFieldsDSLabels\"><strong>CODE<\/strong><\/td>\n<td class=\"extraFieldsDSLabels\"><strong>TYPE PUMP<\/strong><\/td>\n<td class=\"extraFieldsDSLabels\"><strong>PUMP VOLTAGE (Volt)<\/strong><\/td>\n<td class=\"extraFieldsDSLabels\"><strong>MOTOR POWER (kW)<\/strong><\/td>\n<td class=\"extraFieldsDSLabels\"><strong>NOISE<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"extraFieldsDSValues\">S10701253-0<\/td>\n<td class=\"extraFieldsDSValues\">AP\/97-B<\/td>\n<td class=\"extraFieldsDSValues\">1 x 220<\/td>\n<td class=\"extraFieldsDSValues\">0,75<\/td>\n<td class=\"extraFieldsDSValues\">2&#8243; x 2&#8221;<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">S10701254-0<\/td>\n<td class=\"extraFieldsDSValues\">AP\/97-BT<\/td>\n<td class=\"extraFieldsDSValues\">3 x 380<\/td>\n<td class=\"extraFieldsDSValues\">0,75<\/td>\n<td class=\"extraFieldsDSValues\">2&#8243; x 2&#8221;<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">S10701302-0<\/td>\n<td class=\"extraFieldsDSValues\">AP\/97-A<\/td>\n<td class=\"extraFieldsDSValues\">1 x 220<\/td>\n<td class=\"extraFieldsDSValues\">1,1<\/td>\n<td class=\"extraFieldsDSValues\">2&#8243; x 2&#8221;<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">S10701307-0<\/td>\n<td class=\"extraFieldsDSValues\">AP\/97-AT<\/td>\n<td class=\"extraFieldsDSValues\">3 x 380<\/td>\n<td class=\"extraFieldsDSValues\">1,1<\/td>\n<td class=\"extraFieldsDSValues\">2&#8243; x 2&#8221;<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">S14902300-0<\/td>\n<td class=\"extraFieldsDSValues\">AP\/98-A<\/td>\n<td class=\"extraFieldsDSValues\">1 x 220<\/td>\n<td class=\"extraFieldsDSValues\">2,2<\/td>\n<td class=\"extraFieldsDSValues\">2&#8243; x 2&#8221;<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">S14902301-0<\/td>\n<td class=\"extraFieldsDSValues\">AP\/98-AT<\/td>\n<td class=\"extraFieldsDSValues\">3 x 380<\/td>\n<td class=\"extraFieldsDSValues\">2,2<\/td>\n<td class=\"extraFieldsDSValues\">2&#8243; x 2&#8221;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"clr\"><\/div>\n<div class=\"itemExtraFields\">\n<ul>\n<li class=\"even typeTextarea group5 manometrikosemys\">\n<table class=\"specs-table\">\n<thead>\n<tr class=\"tableizer-firstrow\">\n<th colspan=\"14\">PROVISION in m3\/h<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><\/td>\n<td>0<\/td>\n<td>6<\/td>\n<td>9<\/td>\n<td>12<\/td>\n<td>15<\/td>\n<td>18<\/td>\n<td>21<\/td>\n<td>24<\/td>\n<td>27<\/td>\n<td>30<\/td>\n<td>33<\/td>\n<td>36<\/td>\n<td>40<\/td>\n<\/tr>\n<tr>\n<td><strong>CODE NUMBER<\/strong><\/td>\n<td colspan=\"13\"><strong><span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">MANOMETRIC in M.Y.S.<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">(m)<\/span><\/span><\/span><\/strong><\/td>\n<\/tr>\n<tr>\n<td>S10701253-0<\/td>\n<td>12,0<\/td>\n<td>11,0<\/td>\n<td>10,2<\/td>\n<td>9,6<\/td>\n<td>9,0<\/td>\n<td>8,0<\/td>\n<td>7,0<\/td>\n<td>5,8<\/td>\n<td>4,6<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>S10701254-0<\/td>\n<td>12,0<\/td>\n<td>11,0<\/td>\n<td>10,2<\/td>\n<td>9,6<\/td>\n<td>9,0<\/td>\n<td>8,0<\/td>\n<td>7,0<\/td>\n<td>5,8<\/td>\n<td>4,6<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>S10701302-0<\/td>\n<td>16,5<\/td>\n<td>15,0<\/td>\n<td>14,3<\/td>\n<td>13,3<\/td>\n<td>12,0<\/td>\n<td>10,5<\/td>\n<td>8,9<\/td>\n<td>7,2<\/td>\n<td>5,1<\/td>\n<td>3,0<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>S10701307-0<\/td>\n<td>16,5<\/td>\n<td>15,0<\/td>\n<td>14,3<\/td>\n<td>13,3<\/td>\n<td>12,0<\/td>\n<td>10,5<\/td>\n<td>8,9<\/td>\n<td>7,2<\/td>\n<td>5,1<\/td>\n<td>3,0<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>S14902300-0<\/td>\n<td>18,7<\/td>\n<td>17,3<\/td>\n<td>16,6<\/td>\n<td>16,0<\/td>\n<td>15,7<\/td>\n<td>14,5<\/td>\n<td>13,6<\/td>\n<td>12,7<\/td>\n<td>11,8<\/td>\n<td>10,5<\/td>\n<td>9,5<\/td>\n<td>8,3<\/td>\n<td>6,6<\/td>\n<\/tr>\n<tr>\n<td>S14902301-0<\/td>\n<td>18,7<\/td>\n<td>17,3<\/td>\n<td>16,6<\/td>\n<td>16,0<\/td>\n<td>15,7<\/td>\n<td>14,5<\/td>\n<td>13,6<\/td>\n<td>12,7<\/td>\n<td>11,8<\/td>\n<td>10,5<\/td>\n<td>9,5<\/td>\n<td>8,3<\/td>\n<td>6,6<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/li>\n<li class=\"odd typeSelect group5 kataskevastis\"><span class=\"itemExtraFieldsLabel\"><strong>Manufacturer<\/strong>:<\/span> <span class=\"itemExtraFieldsValue\">SAER<\/span><\/li>\n<\/ul>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Horizontal self-priming open impeller pumps with high energy efficiency motors. Suitable for clean and dirty fluids. &nbsp; General characteristics Maximum operating pressure 6 bar Maximum water temperature +70OC. Maximum suction depth 8 m, includes non-return valve. Asynchronous bipolar motor, insulation class F, protection IP44. Single-phase pumps have a built-in start capacitor. &nbsp; Construction materials Pump [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":1989,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[73],"tags":[],"class_list":["post-1988","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-horizontal-automatic-suction"],"_links":{"self":[{"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/posts\/1988","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/comments?post=1988"}],"version-history":[{"count":2,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/posts\/1988\/revisions"}],"predecessor-version":[{"id":1992,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/posts\/1988\/revisions\/1992"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/media\/1989"}],"wp:attachment":[{"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/media?parent=1988"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/categories?post=1988"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/tags?post=1988"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}