{"id":1872,"date":"2023-10-05T08:41:12","date_gmt":"2023-10-05T05:41:12","guid":{"rendered":"https:\/\/roi.gr\/?p=1872"},"modified":"2023-10-05T08:41:12","modified_gmt":"2023-10-05T05:41:12","slug":"horizontal-two-stage-centrifugal-pumps-cb-series","status":"publish","type":"post","link":"https:\/\/roi.gr\/en\/horizontal-two-stage-centrifugal-pumps-cb-series\/","title":{"rendered":"Horizontal two-stage centrifugal pumps CB Series"},"content":{"rendered":"<p>Horizontal two-stage cast iron centrifugal pumps with brass or thermoplastic resin impellers. Suitable for clean liquids, not oxidizing, for water supply, domestic systems, network pressure increase.<\/p>\n<p><strong>General characteristics<\/strong><\/p>\n<p>Maximum suction depth 8 m.<br \/>\nMaximum water temperature +70OC.<br \/>\nAsynchronous bipolar motor, insulation class F, protection IP44.<\/p>\n<p><strong>Construction materials<\/strong><\/p>\n<p>G20 cast iron pump body<br \/>\nThermoplastic resin pump impeller (b.c. brass) y AISI 431 stainless steel pump shaft<br \/>\nGraphite \/ ceramic mechanical seal<\/p>\n<div class=\"desc col-lg-6 col-md-6\">\n<p class=\"manufclogo\"><img decoding=\"async\" src=\"http:\/\/roi-pumps.eu\/images\/partners\/SAER.png\" \/><\/p>\n<\/div>\n<div class=\"desc col-lg-12 col-md-12\">\n<p>&nbsp;<\/p>\n<\/div>\n<div class=\"content\">\n<div class=\"meta fix\"><\/div>\n<div class=\"clr\"><\/div>\n<div class=\"clr\"><\/div>\n<table class=\"extraFieldsDataSets\">\n<thead>\n<tr>\n<td class=\"extraFieldsDSLabels\">CODE<\/td>\n<td class=\"extraFieldsDSLabels\">TYPE PUMP<\/td>\n<td class=\"extraFieldsDSLabels\">PUMP VOLTAGE (Volt)<\/td>\n<td class=\"extraFieldsDSLabels\">MOTOR POWER (kW)<\/td>\n<td class=\"extraFieldsDSLabels\">NOISE<\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"extraFieldsDSValues\">711661002-0<\/td>\n<td class=\"extraFieldsDSValues\">CB 40P<\/td>\n<td class=\"extraFieldsDSValues\">1 x 220<\/td>\n<td class=\"extraFieldsDSValues\">1,1<\/td>\n<td class=\"extraFieldsDSValues\">1 1\/2&#8243; X 1&#8221;<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">711661007-0<\/td>\n<td class=\"extraFieldsDSValues\">CB 40PT<\/td>\n<td class=\"extraFieldsDSValues\">3 x 380<\/td>\n<td class=\"extraFieldsDSValues\">1,1<\/td>\n<td class=\"extraFieldsDSValues\">1 1\/2&#8243; X 1&#8221;<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">711661502-0<\/td>\n<td class=\"extraFieldsDSValues\">CB 50P<\/td>\n<td class=\"extraFieldsDSValues\">1 x 220<\/td>\n<td class=\"extraFieldsDSValues\">1,5<\/td>\n<td class=\"extraFieldsDSValues\">1 1\/2&#8243; X 1&#8221;<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">711661506-0<\/td>\n<td class=\"extraFieldsDSValues\">CB 50PT<\/td>\n<td class=\"extraFieldsDSValues\">3 x 380<\/td>\n<td class=\"extraFieldsDSValues\">1,5<\/td>\n<td class=\"extraFieldsDSValues\">1 1\/2&#8243; X 1&#8221;<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">711662002-0<\/td>\n<td class=\"extraFieldsDSValues\">CB 60P<\/td>\n<td class=\"extraFieldsDSValues\">1 x 220<\/td>\n<td class=\"extraFieldsDSValues\">2,2<\/td>\n<td class=\"extraFieldsDSValues\">1 1\/2&#8243; X 1&#8221;<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">711662003-0<\/td>\n<td class=\"extraFieldsDSValues\">CB 60PT<\/td>\n<td class=\"extraFieldsDSValues\">3 x 380<\/td>\n<td class=\"extraFieldsDSValues\">2,2<\/td>\n<td class=\"extraFieldsDSValues\">1 1\/2&#8243; X 1&#8221;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"clr\"><\/div>\n<div class=\"itemExtraFields\">\n<ul>\n<li class=\"even typeTextarea group5 manometrikosemys\">\n<table class=\"specs-table\">\n<thead>\n<tr class=\"tableizer-firstrow\">\n<th colspan=\"10\"><strong>DELIVERY in m3\/h<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><\/td>\n<td>0,0<\/td>\n<td>1,0<\/td>\n<td>3,0<\/td>\n<td>5,0<\/td>\n<td>7,0<\/td>\n<td>9,0<\/td>\n<td>10,0<\/td>\n<td>12,0<\/td>\n<td>14,0<\/td>\n<\/tr>\n<tr>\n<td><strong>CODE NUMBER<\/strong><\/td>\n<td colspan=\"9\"><strong><span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">MANOMETRIC in M.Y.S.<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">(m)<\/span><\/span><\/span><\/strong><\/td>\n<\/tr>\n<tr>\n<td>711661002-0<\/td>\n<td>41<\/td>\n<td>42<\/td>\n<td>42<\/td>\n<td>40<\/td>\n<td>36<\/td>\n<td>30<\/td>\n<td>25<\/td>\n<td>15<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>711661007-0<\/td>\n<td>41<\/td>\n<td>42<\/td>\n<td>42<\/td>\n<td>40<\/td>\n<td>36<\/td>\n<td>30<\/td>\n<td>25<\/td>\n<td>15<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>711661502-0<\/td>\n<td>50<\/td>\n<td>49<\/td>\n<td>49<\/td>\n<td>48<\/td>\n<td>45<\/td>\n<td>40<\/td>\n<td>36<\/td>\n<td>28<\/td>\n<td>17<\/td>\n<\/tr>\n<tr>\n<td>711661506-0<\/td>\n<td>50<\/td>\n<td>49<\/td>\n<td>49<\/td>\n<td>48<\/td>\n<td>45<\/td>\n<td>40<\/td>\n<td>36<\/td>\n<td>28<\/td>\n<td>17<\/td>\n<\/tr>\n<tr>\n<td>711662002-0<\/td>\n<td>64<\/td>\n<td>62<\/td>\n<td>59<\/td>\n<td>55<\/td>\n<td>48<\/td>\n<td>40<\/td>\n<td>35<\/td>\n<td>23<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td>711662003-0<\/td>\n<td>64<\/td>\n<td>62<\/td>\n<td>59<\/td>\n<td>55<\/td>\n<td>48<\/td>\n<td>40<\/td>\n<td>35<\/td>\n<td>23<\/td>\n<td>8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/li>\n<li class=\"odd typeSelect group5 kataskevastis\"><span class=\"itemExtraFieldsLabel\"><strong>Manufacturer<\/strong>:<\/span> <span class=\"itemExtraFieldsValue\">SAER<\/span><\/li>\n<\/ul>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Horizontal two-stage cast iron centrifugal pumps with brass or thermoplastic resin impellers. Suitable for clean liquids, not oxidizing, for water supply, domestic systems, network pressure increase. General characteristics Maximum suction depth 8 m. Maximum water temperature +70OC. Asynchronous bipolar motor, insulation class F, protection IP44. Construction materials G20 cast iron pump body Thermoplastic resin pump [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":1873,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[68],"tags":[],"class_list":["post-1872","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-two-stage-centrifuges"],"_links":{"self":[{"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/posts\/1872","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/comments?post=1872"}],"version-history":[{"count":3,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/posts\/1872\/revisions"}],"predecessor-version":[{"id":1877,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/posts\/1872\/revisions\/1877"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/media\/1873"}],"wp:attachment":[{"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/media?parent=1872"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/categories?post=1872"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/tags?post=1872"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}