{"id":1740,"date":"2023-10-02T10:03:28","date_gmt":"2023-10-02T07:03:28","guid":{"rendered":"https:\/\/roi.gr\/?p=1740"},"modified":"2023-10-02T10:03:28","modified_gmt":"2023-10-02T07:03:28","slug":"horizontal-single-stage-centrifugal-pumps-bp-11-12-series","status":"publish","type":"post","link":"https:\/\/roi.gr\/en\/horizontal-single-stage-centrifugal-pumps-bp-11-12-series\/","title":{"rendered":"Horizontal single-stage centrifugal pumps BP 11-12 Series"},"content":{"rendered":"<p>Horizontal single-stage cast iron centrifugal pumps with brass or cast iron impellers. Suitable for agricultural and industrial applications, for water supply or transport, network pressure increase.<\/p>\n<p><strong>General characteristics<\/strong><\/p>\n<p>Maximum operating pressure 6 bar for BP 3-4-5-6 \/ 10 bar for BP 7-8-9-13-14-15-16-17<br \/>\nMaximum suction depth 6-7m<br \/>\nMaximum water temperature +70OC for BP 3-4-5-6 \/ +120OC BP 7-8-9-13-14-15-16-17<br \/>\nAsynchronous bipolar motor, insulation class F, protection IP44 for BP 3-4-5-6-7 \/ IP55 for BP 9-10-11-12-13-14-15-16-17<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Construction materials<\/strong><\/p>\n<p>G20 cast iron pump body<br \/>\nG20 Cast Iron \/ Brass Pump Impeller<br \/>\nAISI 420B \/ AISI 431 stainless steel pump shaft<br \/>\nGraphite \/ ceramic mechanical seal<\/p>\n<div class=\"desc col-lg-6 col-md-6\">\n<p>&nbsp;<\/p>\n<p class=\"manufclogo\"><img decoding=\"async\" src=\"http:\/\/roi-pumps.eu\/images\/partners\/SAER.png\" \/><\/p>\n<\/div>\n<div class=\"desc col-lg-12 col-md-12\">\n<p>&nbsp;<\/p>\n<\/div>\n<div class=\"content\">\n<div class=\"meta fix\"><\/div>\n<div class=\"clr\"><\/div>\n<div class=\"clr\"><\/div>\n<table class=\"extraFieldsDataSets\">\n<thead>\n<tr>\n<td class=\"extraFieldsDSLabels\"><\/td>\n<td class=\"extraFieldsDSLabels\"><\/td>\n<td class=\"extraFieldsDSLabels\"><\/td>\n<\/tr>\n<\/thead>\n<\/table>\n<\/div>\n<table class=\"extraFieldsDataSets\">\n<thead>\n<tr>\n<td class=\"extraFieldsDSLabels\"><strong>CODE <\/strong><\/td>\n<td class=\"extraFieldsDSLabels\"><strong>TYPE PUMP<\/strong><\/td>\n<td class=\"extraFieldsDSLabels\"><strong>PUMP VOLTAGE (Volt)<\/strong><\/td>\n<td class=\"extraFieldsDSLabels\"><strong>MOTOR POWER (kW)<\/strong><\/td>\n<td class=\"extraFieldsDSLabels\"><strong>NOISE<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"extraFieldsDSValues\">711581121-0<\/td>\n<td class=\"extraFieldsDSValues\">BP 11NC<\/td>\n<td class=\"extraFieldsDSValues\">3 x 380<\/td>\n<td class=\"extraFieldsDSValues\">3<\/td>\n<td class=\"extraFieldsDSValues\">2 1\/2&#8221; X 2&#8221;<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">711581141-0<\/td>\n<td class=\"extraFieldsDSValues\">BP 11NB<\/td>\n<td class=\"extraFieldsDSValues\">3 x 380<\/td>\n<td class=\"extraFieldsDSValues\">4<\/td>\n<td class=\"extraFieldsDSValues\">2 1\/2&#8221; X 2&#8221;<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">711581160-0<\/td>\n<td class=\"extraFieldsDSValues\">BP 11NA<\/td>\n<td class=\"extraFieldsDSValues\">3 x 380<\/td>\n<td class=\"extraFieldsDSValues\">5,5<\/td>\n<td class=\"extraFieldsDSValues\">2 1\/2&#8221; X 2&#8221;<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">711581180-0<\/td>\n<td class=\"extraFieldsDSValues\">BP 12C<\/td>\n<td class=\"extraFieldsDSValues\">3 x 380<\/td>\n<td class=\"extraFieldsDSValues\">4<\/td>\n<td class=\"extraFieldsDSValues\">2 1\/2&#8221; X 2&#8221;<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">711581200-0<\/td>\n<td class=\"extraFieldsDSValues\">BP 12B<\/td>\n<td class=\"extraFieldsDSValues\">3 x 380<\/td>\n<td class=\"extraFieldsDSValues\">5,5<\/td>\n<td class=\"extraFieldsDSValues\">2 1\/2&#8221; X 2&#8221;<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">711581220-0<\/td>\n<td class=\"extraFieldsDSValues\">BP 12A<\/td>\n<td class=\"extraFieldsDSValues\">3 x 380<\/td>\n<td class=\"extraFieldsDSValues\">7,5<\/td>\n<td class=\"extraFieldsDSValues\">2 1\/2&#8221; X 2&#8221;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<div class=\"itemExtraFields\">\n<ul>\n<li class=\"even typeTextarea group5 manometrikosemys\">\n<table class=\"specs-table\">\n<thead>\n<tr class=\"tableizer-firstrow\">\n<th colspan=\"11\">\u00a0DELIVERY IN m3\/h<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><\/td>\n<td>0<\/td>\n<td>12<\/td>\n<td>16<\/td>\n<td>20<\/td>\n<td>25<\/td>\n<td>30<\/td>\n<td>35<\/td>\n<td>40<\/td>\n<td>45<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td><strong>CODE NUMBER<br \/>\n<\/strong><\/td>\n<td colspan=\"10\"><strong>MANOMETRIC in M.Y.S. (m)<\/strong><\/td>\n<\/tr>\n<tr>\n<td>711581121-0<\/td>\n<td>31,5<\/td>\n<td>30,6<\/td>\n<td>30,3<\/td>\n<td>29,8<\/td>\n<td>28,0<\/td>\n<td>27,5<\/td>\n<td>26,5<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>711581141-0<\/td>\n<td>35,5<\/td>\n<td>35,0<\/td>\n<td>34,7<\/td>\n<td>33,7<\/td>\n<td>33,0<\/td>\n<td>31,7<\/td>\n<td>30,0<\/td>\n<td>28,5<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>711581160-0<\/td>\n<td>38,6<\/td>\n<td>38,0<\/td>\n<td>37,6<\/td>\n<td>37,3<\/td>\n<td>36,2<\/td>\n<td>35,5<\/td>\n<td>34,0<\/td>\n<td>32,5<\/td>\n<td>30,8<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>711581180-0<\/td>\n<td>45,0<\/td>\n<td>43,9<\/td>\n<td>43,5<\/td>\n<td>41,2<\/td>\n<td>37,3<\/td>\n<td>33,5<\/td>\n<td>28,2<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>711581200-0<\/td>\n<td>47,5<\/td>\n<td>47,4<\/td>\n<td>47,1<\/td>\n<td>45,6<\/td>\n<td>42,5<\/td>\n<td>39,9<\/td>\n<td>35,6<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>711581220-0<\/td>\n<td>57,5<\/td>\n<td>56,9<\/td>\n<td>56,5<\/td>\n<td>55,1<\/td>\n<td>53,0<\/td>\n<td>50,0<\/td>\n<td>46,5<\/td>\n<td>39,5<\/td>\n<td>31,7<\/td>\n<td>21,0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/li>\n<\/ul>\n<\/div>\n<p>Manufacturer: SAER<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Horizontal single-stage cast iron centrifugal pumps with brass or cast iron impellers. Suitable for agricultural and industrial applications, for water supply or transport, network pressure increase. General characteristics Maximum operating pressure 6 bar for BP 3-4-5-6 \/ 10 bar for BP 7-8-9-13-14-15-16-17 Maximum suction depth 6-7m Maximum water temperature +70OC for BP 3-4-5-6 \/ +120OC [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":1741,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[67],"tags":[],"class_list":["post-1740","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-single-stage-centrifuges"],"_links":{"self":[{"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/posts\/1740","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/comments?post=1740"}],"version-history":[{"count":2,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/posts\/1740\/revisions"}],"predecessor-version":[{"id":1744,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/posts\/1740\/revisions\/1744"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/media\/1741"}],"wp:attachment":[{"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/media?parent=1740"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/categories?post=1740"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/tags?post=1740"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}