{"id":1700,"date":"2023-09-18T10:54:56","date_gmt":"2023-09-18T07:54:56","guid":{"rendered":"https:\/\/roi.gr\/?p=1700"},"modified":"2023-10-06T09:27:28","modified_gmt":"2023-10-06T06:27:28","slug":"horizontal-centrifugal-pumps-fc-25-series","status":"publish","type":"post","link":"https:\/\/roi.gr\/en\/horizontal-centrifugal-pumps-fc-25-series\/","title":{"rendered":"Horizontal centrifugal pumps FC 25 Series"},"content":{"rendered":"<p>Horizontal cast iron centrifugal pumps with two opposing brass impellers. Suitable for urban, industrial use, in air conditioning-heating and cooling installations.<\/p>\n<p>General characteristics<\/p>\n<p>Maximum suction depth 8 m with foot valve<br \/>\nMaximum water temperature +70 C<br \/>\nAsynchronous bipolar motor, insulation class F, protection IP44<\/p>\n<p>Construction materials<\/p>\n<p>G20 cast iron pump body<br \/>\nBrass pump impeller<br \/>\nAISI 431 stainless steel pump shaft y Graphite \/ ceramic mechanical seal<\/p>\n<p class=\"manufclogo\"><img decoding=\"async\" src=\"http:\/\/roi-pumps.eu\/images\/partners\/SAER.png\" \/><\/p>\n<table class=\"extraFieldsDataSets\">\n<thead>\n<tr>\n<td class=\"extraFieldsDSLabels\"><strong>CODE PUMP<br \/>\n<\/strong><\/td>\n<td class=\"extraFieldsDSLabels\"><strong>TYPE PUMP<\/strong><\/td>\n<td class=\"extraFieldsDSLabels\"><strong> VOLTAGE <\/strong>(Volt)<\/td>\n<td class=\"extraFieldsDSLabels\"><strong>MOTOR POWER<\/strong> (kW)<\/td>\n<td class=\"extraFieldsDSLabels\"><strong>NOISE<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"extraFieldsDSValues\">711620761-0<\/td>\n<td class=\"extraFieldsDSValues\">FC 25-2D<\/td>\n<td class=\"extraFieldsDSValues\">1 x 220<\/td>\n<td class=\"extraFieldsDSValues\">1,1<\/td>\n<td class=\"extraFieldsDSValues\">1 1\/4\u2033 X 1\u201d<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">711620759-0<\/td>\n<td class=\"extraFieldsDSValues\">FC 25-2D T<\/td>\n<td class=\"extraFieldsDSValues\">3 x 380<\/td>\n<td class=\"extraFieldsDSValues\">1,1<\/td>\n<td class=\"extraFieldsDSValues\">1 1\/4\u2033 X 1\u201d<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">711620611-0<\/td>\n<td class=\"extraFieldsDSValues\">FC 25-2F<\/td>\n<td class=\"extraFieldsDSValues\">1 x 220<\/td>\n<td class=\"extraFieldsDSValues\">1,1<\/td>\n<td class=\"extraFieldsDSValues\">1 1\/4\u2033 X 1\u201d<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">711620612-0<\/td>\n<td class=\"extraFieldsDSValues\">FC 25-2F T<\/td>\n<td class=\"extraFieldsDSValues\">3 x 380<\/td>\n<td class=\"extraFieldsDSValues\">1,1<\/td>\n<td class=\"extraFieldsDSValues\">1 1\/4\u2033 X 1\u201d<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">711620506-0<\/td>\n<td class=\"extraFieldsDSValues\">FC 25-2C<\/td>\n<td class=\"extraFieldsDSValues\">1 x 220<\/td>\n<td class=\"extraFieldsDSValues\">1,5<\/td>\n<td class=\"extraFieldsDSValues\">1 1\/4\u2033 X 1\u201d<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">711620511-0<\/td>\n<td class=\"extraFieldsDSValues\">FC 25-2C T<\/td>\n<td class=\"extraFieldsDSValues\">3 x 380<\/td>\n<td class=\"extraFieldsDSValues\">1,5<\/td>\n<td class=\"extraFieldsDSValues\">1 1\/4\u2033 X 1\u201d<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">711620313-0<\/td>\n<td class=\"extraFieldsDSValues\">FC 25-2E<\/td>\n<td class=\"extraFieldsDSValues\">1 x 220<\/td>\n<td class=\"extraFieldsDSValues\">1,5<\/td>\n<td class=\"extraFieldsDSValues\">1 1\/4\u2033 X 1\u201d<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">711620312-0<\/td>\n<td class=\"extraFieldsDSValues\">FC 25-2E T<\/td>\n<td class=\"extraFieldsDSValues\">3 x 380<\/td>\n<td class=\"extraFieldsDSValues\">1,5<\/td>\n<td class=\"extraFieldsDSValues\">1 1\/4\u2033 X 1\u201d<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">711620249-0<\/td>\n<td class=\"extraFieldsDSValues\">FC 25-2B<\/td>\n<td class=\"extraFieldsDSValues\">1 x 220<\/td>\n<td class=\"extraFieldsDSValues\">2,2<\/td>\n<td class=\"extraFieldsDSValues\">1 1\/4\u2033 X 1\u201d<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">711620252-0<\/td>\n<td class=\"extraFieldsDSValues\">FC 25-2BT<\/td>\n<td class=\"extraFieldsDSValues\">3 x 380<\/td>\n<td class=\"extraFieldsDSValues\">2,2<\/td>\n<td class=\"extraFieldsDSValues\">1 1\/4\u2033 X 1\u201d<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">711620013-0<\/td>\n<td class=\"extraFieldsDSValues\">FC 25-2A<\/td>\n<td class=\"extraFieldsDSValues\">3 x 380<\/td>\n<td class=\"extraFieldsDSValues\">3,0<\/td>\n<td class=\"extraFieldsDSValues\">1 1\/4\u2033 X 1\u201d<\/td>\n<\/tr>\n<tr>\n<td class=\"extraFieldsDSValues\">711620007-0<\/td>\n<td class=\"extraFieldsDSValues\">FC 25-2AT<\/td>\n<td class=\"extraFieldsDSValues\">3 x 380<\/td>\n<td class=\"extraFieldsDSValues\">3,0<\/td>\n<td class=\"extraFieldsDSValues\">1 1\/4\u2033 X 1\u201d<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"clr\"><\/div>\n<div class=\"itemExtraFields\">\n<ul>\n<li class=\"even typeTextarea group5 manometrikosemys\">\n<table class=\"specs-table\">\n<thead>\n<tr class=\"tableizer-firstrow\">\n<th colspan=\"10\">CAPACITY in m3\/h<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><\/td>\n<td>0,0<\/td>\n<td>2,0<\/td>\n<td>4,0<\/td>\n<td>5,0<\/td>\n<td>6,0<\/td>\n<td>7,0<\/td>\n<td>8,0<\/td>\n<td>9,0<\/td>\n<td>10,0<\/td>\n<\/tr>\n<tr>\n<td><strong>CODE NUMBER<\/strong><\/td>\n<td colspan=\"9\"><strong>MANOMETRIC in M.Y.S. (m)<\/strong><\/td>\n<\/tr>\n<tr>\n<td>711620761-0<\/td>\n<td>44<\/td>\n<td>42<\/td>\n<td>38<\/td>\n<td>35<\/td>\n<td>30<\/td>\n<td>23,5<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>711620759-0<\/td>\n<td>44<\/td>\n<td>42<\/td>\n<td>38<\/td>\n<td>35<\/td>\n<td>30<\/td>\n<td>23,5<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>711620611-0<\/td>\n<td>51<\/td>\n<td>47<\/td>\n<td>42,5<\/td>\n<td>40<\/td>\n<td>38<\/td>\n<td>34<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>711620612-0<\/td>\n<td>51<\/td>\n<td>47<\/td>\n<td>42,5<\/td>\n<td>40<\/td>\n<td>38<\/td>\n<td>34<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>711620506-0<\/td>\n<td>52,5<\/td>\n<td>49,5<\/td>\n<td>45<\/td>\n<td>44<\/td>\n<td>41<\/td>\n<td>36<\/td>\n<td>33<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>711620511-0<\/td>\n<td>52,5<\/td>\n<td>49,5<\/td>\n<td>45<\/td>\n<td>44<\/td>\n<td>41<\/td>\n<td>36<\/td>\n<td>33<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>711620313-0<\/td>\n<td>61,5<\/td>\n<td>55<\/td>\n<td>47,5<\/td>\n<td>45<\/td>\n<td>41,5<\/td>\n<td>39<\/td>\n<td>34<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>711620312-0<\/td>\n<td>61,5<\/td>\n<td>55<\/td>\n<td>47,5<\/td>\n<td>45<\/td>\n<td>41,5<\/td>\n<td>39<\/td>\n<td>34<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>711620249-0<\/td>\n<td>64<\/td>\n<td><\/td>\n<td>57<\/td>\n<td>54,5<\/td>\n<td>51<\/td>\n<td>47<\/td>\n<td>42,5<\/td>\n<td>36,5<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>711620252-0<\/td>\n<td>64<\/td>\n<td><\/td>\n<td>57<\/td>\n<td>54,5<\/td>\n<td>51<\/td>\n<td>47<\/td>\n<td>42,5<\/td>\n<td>36,5<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>711620013-0<\/td>\n<td>70<\/td>\n<td><\/td>\n<td>64<\/td>\n<td>62<\/td>\n<td>59,5<\/td>\n<td>56,5<\/td>\n<td>52,5<\/td>\n<td>48<\/td>\n<td>42,5<\/td>\n<\/tr>\n<tr>\n<td>711620007-0<\/td>\n<td>70<\/td>\n<td><\/td>\n<td>64<\/td>\n<td>62<\/td>\n<td>59,5<\/td>\n<td>56,5<\/td>\n<td>52,5<\/td>\n<td>48<\/td>\n<td>42,5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/li>\n<li class=\"odd typeSelect group5 kataskevastis\"><span class=\"itemExtraFieldsLabel\">Manufacturer:<\/span> <span class=\"itemExtraFieldsValue\">SAER<\/span><\/li>\n<\/ul>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Horizontal cast iron centrifugal pumps with two opposing brass impellers. Suitable for urban, industrial use, in air conditioning-heating and cooling installations. General characteristics Maximum suction depth 8 m with foot valve Maximum water temperature +70 C Asynchronous bipolar motor, insulation class F, protection IP44 Construction materials G20 cast iron pump body Brass pump impeller AISI [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":1701,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[67],"tags":[],"class_list":["post-1700","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-single-stage-centrifuges"],"_links":{"self":[{"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/posts\/1700","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/comments?post=1700"}],"version-history":[{"count":4,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/posts\/1700\/revisions"}],"predecessor-version":[{"id":1962,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/posts\/1700\/revisions\/1962"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/media\/1701"}],"wp:attachment":[{"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/media?parent=1700"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/categories?post=1700"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/roi.gr\/en\/wp-json\/wp\/v2\/tags?post=1700"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}